Pure Micro Series FAQ

How can I switch the different modes of the Advanced Scan Fail Safety?

 The Advanced Scan Fail Safety of the Xscan scanners can be switched to three different modes: The Fail Safety mode permanently checks if the scanner output matches the input signal. If there is any deviation, it switches of the laser output.The Beam Block Safety mode completely blocks every focussed beam (threshold can be adjusted) and also has the Fail Safety functions enabled.As third option...

Why is there no key switch at the Pure Micro units?

The requirement for the possibility of preventing unauthorized operation of the laser system is defined in the international laser safety regulation IEC 60825-1. It says that measures must be taken to safely lock the laser system, so a use by third party is not possible.As the Pure Micro units don't have any own built-in intelligence, but work over ILDA control, they cannot be operated without a...

Why is there no interlock connector at the Pure Micro units?

 There is an interlock connector, however it is integrated in the ILDA signal line. On ILDA pin 4 and 17 the interlock signal is transmitted. By interrupting the interlock line, the laser is shut off immediately. This can either be achieved by simply unplugging the ILDA interface or by using the Interlock adapter to get the option of connecting an external shut-off button (like the SAFETY Unit)